Type 1CD 1-way, copper side break switch
SK0110151CD 69kV, 600A & 1200A, Laminated Wood Pole
Adobe PDF | 91KB
SK9511081CD 138kV, 600A & 1200A, Laminated Wood Pole
Adobe PDF | 92KB
SK9404081CD 15kV, 600A & 1200A, Wood Pole
Adobe PDF | 242KB
SK425741CD 69kV, 600A & 1200A, Wood Pole
Adobe PDF | 330KB
SK0005141CD 161kV, 600A & 1200A, Wood Pole
Adobe PDF | 0KB
SK0102021CD 34kV, 600A & 1200A, Concrete Pole
Adobe PDF | 76KB
SK9709151CD 69kV, 600A & 1200A, Concrete Pole
Adobe PDF | 100KB
SK9203101CD 115kV, 1200A, Concrete Pole
Adobe PDF | 111KB
SK0209151CD 138kV, 1200A, Concrete Pole
Adobe PDF | 94KB
SK9706241CD 115kV, 1200A
Adobe PDF | 108KB
SK0305051CD 46kV, 600A & 1200A, Light Duty
Adobe PDF | 89KB
SK9902011CD 69kV, 600A & 1200A, Light Duty
Adobe PDF | 125KB
SK9806181CD 138kV, 1200A, Light Duty
Adobe PDF | 103KB
SK9409241CDF 34kV, 600A, Wood Pole
Adobe PDF | 69KB
SK9503171CDF 46kV, 600A & 1200A, Wood Pole
Adobe PDF | 67KB
SK8408031CDF 69kV, 600A & 1200A, Wood Pole
Adobe PDF | 346KB
SK0206151CDF 115kV, 1200A, Concrete Pole
Adobe PDF | 85KB
SK9307041CDF 161kV, 1200A
Adobe PDF | 81KB
SK9511121CDT 138kV, 1200A, Laminated Wood Pole
Adobe PDF | 101KB
SK9804061CDT 46kV, 600A & 1200A, Wood Pole
Adobe PDF | 82KB
SK8002271CDT 69kV, 600A & 1200A, Wood Pole
Adobe PDF | 127KB
SK73751CDT 115kV, 600A & 1200A, Wood Pole
Adobe PDF | 109KB
SK9608261CDT 46kV, 600A & 1200A, Concrete Pole
Adobe PDF | 84KB
SK0110171CDT 46kV, 600A & 1200A
Adobe PDF | 91KB
SK9706261CDT 69kV, 600A & 1200A
Adobe PDF | 0KB
SK9308091CDT 161kV, 600A & 1200A
Adobe PDF | 98KB
SK0008201CDT 69kV, 600A & 1200A, Light Duty
Adobe PDF | 130KB
SK9805011CDT 115kV, 600A & 1200A, Light Duty
Adobe PDF | 125KB
SK9712041CDT 138kV, 600A & 1200A, Light Duty
Adobe PDF | 109KB
1CD
One Way Copper
Copper construction, field-proven performance and phase-over-phase designs.
Turner’s Type 1CD side break switch is well suited for phase-over-phase applications, phase-next-to-phase and triangular configurations on the transmission system. Unlike many so-called transmission-switching products that are merely substation switches modified for use on the transmission system, the Type 1CD is a true transmission switch. It is designed and built for the harsh environmental conditions, galloping conductors and constant pole movement inherent in severe aerial applications.
The 1CD switch configuration is the most versatile. Designed as a “stock switch” suitable for almost any application, The conductor deadends right to the frame. Phase-over-phase, pole-saving triangular and delta mouting configurations are available. Line configurations such as tangent and 90-degree corner are easily handled. If the line is to be deadended to the pole, a “front mount” frame which moves the vertical operating pipe off of the thru-line pole face is available.
Turner Type 1CD switches can be used for station isolating and bypassing, distribution and transmission line sectionalizing or isolating arrestors, metering equipment and other apparatus. Right hand or left hand opening can be specified at time of order. They are easily upgraded for automatic operation and load breaking.
Secure Blade Closing
Turner Type 1CD switches firmly close into position, with the blade tip engaging the jaws with sufficient force to expand the contact jaws, preventing any blade bounce. Both the blade and jaw contacts are wiped clean during the closing action to ensure a low resistance current transfer. A heavy-duty blade-locking device keeps the blade closed despite temporary faults, surge currents, twisting structures or galloping conductors.
The lock is released during the switch opening sequence. This action, exclusive to Turner 1CD switches, breaks up any ice or contamination, and releases the contact friction, allowing the blade to easily be removed from the contacts.
Make Your Side Break a Load-Break Switch
For more than 35 years, Turner Electric’s TECO-Rupter® Vacuum Interrupters have been the technology of choice for loop and load-break applications because of their current-interrupting ability, superior reliability and ease of application.
The TECO-Rupter offers industry leading performance levels including superior TRV ratings compared to other load-break technologies such as SF6, longer service life and greater interrupting capacity. No other load-break device provides 5,000 full load operations at either 2,000 or 3,000 Ampere ratings and a TRV rating up to 57kV.
Ordering Information |
|||||||
| Switch Rating | Station Post Insulators | Catalog Number | |||||
| Voltage | Continuous Current |
Peak Amps | Technical Reference # |
Phase-Over-Phase Mounting |
Delta Mounting |
||
| 15kV | 600 | 65,000 | TR205 | 1CD01506 | 1CDT01506 | ||
| 1200 | 99,000 | 1CD01512 | 1CDT01512 | ||||
| 2000 | 164,000 | 1CD01520 | 1CDT01520 | ||||
| 23kV | 600 | 65,000 | TR208 | 1CD02306 | 1CDT02306 | ||
| 1200 | 99,000 | 1CD02312 | 1CDT02312 | ||||
| 2000 | 164,000 | 1CD02320 | 1CDT02320 | ||||
| 34kV | 600 | 65,000 | TR210 | 1CD03406 | 1CDT03406 | ||
| 1200 | 99,000 | 1CD03412 | 1CDT03412 | ||||
| 2000 | 164,000 | 1CD03420 | 1CDT03420 | ||||
| 46kV | 600 | 65,000 | TR214 | 1CD04606 | 1CDT04606 | ||
| 1200 | 99,000 | 1CD04612 | 1CDT04612 | ||||
| 2000 | 164,000 | 1CD04620 | 1CDT04620 | ||||
| 69kV | 600 | 65,000 | TR216 | 1CD06906 | 1CDT06906 | ||
| 1200 | 99,000 | 1CD06912 | 1CDT06912 | ||||
| 2000 | 164,000 | 1CD06920 | 1CDT06920 | ||||
| 115kV | 600 | 65,000 | TR286 | 1CD11506 | 1CDT11506 | ||
| 1200 | 99,000 | 1CD11512 | 1CDT11512 | ||||
| 2000 | 164,000 | 1CD11520 | 1CDT11520 | ||||
| 138kV | 600 | 65,000 | TR288 | 1CD13806 | 1CDT13806 | ||
| 1200 | 99,000 | 1CD13812 | 1CDT13812 | ||||
| 2000 | 164,000 | 1CD13820 | 1CDT13820 | ||||
| 161kV | 600 | 65,000 | TR291 | 1CD16106 | 1CDT16106 | ||
| 1200 | 99,000 | 1CD16112 | 1CDT16112 | ||||
| 2000 | 164,000 | 1CD16120 | 1CDT16120 | ||||