Catalogs  |  Customer Service  |  Contacts  |  Site Map
Consult factory.

Substation

TDEB

Double-End
Break Switch

Aluminum TDEB Double-End
Break Switch

Type: TDEB
Orientation: Upright or vertical mounting
Ratings: 15 through 345kV
Ratings A: 600, 1200 and 2000 Amperes
Turner Type TDEB switches are a heavy-duty, Double End Break Aluminum design that is most frequently applied when space is at a premium.

Turner has accumulated more than 50 years of proven field experience in air break switches. That means you get an easily installed, easily operated heavy-duty switch that provides maximum mechanical and electrical performance under all operating conditions.

The TDEB switch is normally used at the same phase spacing as a Vertical break switch, as blade potential floats at about 40 percent of normal line-to-ground voltage when the blades are open. Structure width is minimized, as a result. Overhead clearance is also minimized, due to the side-blade-opening characteristics.

Heavy-duty construction, proven reliability and ease of operation make the family of TDEB switches perfect for demanding substation and line operations such as breaker isolating and bypassing; transmission line and bus sectionalizing; and isolating arrestors, metering equipment and other apparatus.

Internal construction is simple, and virtually maintenance-free. The ball bearing assembly on the rotating center stack provides smooth, easy operation, in either the horizontal or Vertical mounting positions.

Group operation for substation and transmission application is accomplished with an interphase pipe, group-operated control pipe, outboard bearing, Vertical operating pipe and swing handle operator.

Reverse-loop contacts
Turner's TDEB switch jaw contacts increase their holding power under resistance. Reverse-loop, silver-plated copper jaw contacts employ the natural repulsion of magnetic fields moving in opposite directions to exert holding forces against the blade edges. In fault conditions, the increased current flow increases the pressure, retaining the blade in the jaws.

TDEB Blade
The aluminum tubular blade design provides the proper combination of current-carrying capacity and rigidity. Silver-plated copper blade tips are easily field-replaceable, as are stationary and moving arcing horns.

Turner TDEB switches gently close into position, with the blade tip engaging the jaws at a 30 degree angle, then rotating to engage the jaw contacts. They are not slammed under force into the contacts. Both the blade and jaw contacts are wiped clean during the closing action to ensure a low resistance current transfer. A heavy-duty static blade-locking device keeps the blade closed despite temporary faults, surge currents, twisting structures or galloping conductors.

The lock is released during the switch opening sequence, as the blade rotates 30 degrees in the jaw. This action text was removed breaks up any ice or contamination, and releases the contact friction, allowing the blade to easily be removed from the contacts.

Insulators
NEMA standard strength gray porcelain insulators of the same voltage rating as the switch will be furnished unless otherwise specified.

Base
Standard bases are hot-dipped, galvanized, rigid, steel sections. Lifetime bearings, requiring no lubrication, and open-close stops are built into the compact assembly. Padlockable swing handle with ground shunt.

Make Your Double-End Break a Load-Break Switch
For more than 35 years, Turner Electric's TECO-Rupter® Vacuum Interrupters have been the technology of choice for loop and load-break applications because of their current-interrupting ability, superior reliability and ease of application.

The TECO-Rupter offers industry leading performance levels including superior TRV ratings compared to other load-break technologies such as SF6, longer service life and greater interrupting capacity. No other load-break device provides 5,000 full load operations at either 2,000 or 3,000 Ampere ratings and a TRV rating up to 57kV.

Ordering Information

 
  Switch Rating Station Post Insulators Catalog Number  
 
 VoltageContinuous
Current
Technical
Reference #
Aluminum 
 466002141TDEB04606 
12001TDEB04612 
20001TDEB04620 
 696002161TDEB06906 
12001TDEB06912 
20001TDEB06920 
 1156002861TDEB11506 
12001TDEB11512 
20001TDEB11520 
 1386002881TDEB13806 
12001TDEB13812 
20001TDEB13820 
 1616002911TDEB16106 
12001TDEB16112 
20001TDEB16120 
 2306003041TDEB23006 
12001TDEB23012 
20001TDEB23020